ECO POWER SERVICESWe get the signal from the noise

We get the signal from the noise.

Installation, testing and commissioning for MV, HV and EHV substations, industry, oil & gas, and solar + BESS projects across Egypt.

  • MV
  • HV
  • EHV
  • Solar + BESS
  • Oil & Gas

Track record in numbers

Field-proven across solar farms, substations and industrial sites in Egypt.

+250OC & EF relays tested
+250MV switchgear bays commissioned (6.6–33 kV)
+50advanced relays: distance, transformer differential, busbar
+75bays tested at 66 kV
+40bays tested at 220 kV
+500MWof solar projects tested

Services

From first installation to energization, across every voltage level: 500, 220, 66, 33, 22, 11 and 6.6 kV.

  • 500 kV
  • 220 kV
  • 66 kV
  • 33 kV
  • 22 kV
  • 11 kV
  • 6.6 kV
ON SITE · EGYPT
Site-ready teams: MV switchgear commissioning on a live project
01 / 05Site-ready teamsMV switchgear commissioning on a live project
Breaker timing & contact resistance: Primary tests on a vacuum circuit breaker
02 / 05Breaker timing & contact resistancePrimary tests on a vacuum circuit breaker
Relay secondary injection: Test set and software verify every protection function
03 / 05Relay secondary injectionTest set and software verify every protection function
CT / VT testing & bay checks: Test set connected at the MV switchgear line-up
04 / 05CT / VT testing & bay checksTest set connected at the MV switchgear line-up
Interlocks, schemes & drawings: Every check traced against the approved drawings
05 / 05Interlocks, schemes & drawingsEvery check traced against the approved drawings
SERVICE 01

Substation testing & commissioning

Circuit breaker timing and contact resistance, CT/VT/CCVT, surge arresters, disconnectors, scheme and functional checks, interlocks, and energy meters.

  • Site-ready team
  • Circuit breaker timing & contact resistance
  • Relay & scheme functional checks
  • CT / VT / CCVT & disconnectors
  • Interlocks & energy meters
Get a quote for your substation
ON SITE · EGYPT
Secondary injection on site: Test set and laptop drive the relay through its settings
01 / 01Secondary injection on siteTest set and laptop drive the relay through its settings
INJECTION TEST · ILLUSTRATION
SERVICE 02

Protection relay testing

Primary and secondary injection, relay settings verification, and end-to-end checks so protection operates correctly and failures do not cascade.

  • Primary injection
  • Secondary injection
  • Relay settings verification
  • End-to-end checks, so failures do not cascade
Discuss your protection scheme
ON SITE · EGYPT
Power transformer services: From ratio tests to oil filtration and maintenance
01 / 01Power transformer servicesFrom ratio tests to oil filtration and maintenance
SERVICE 03

Power transformer services

Turns ratio, vector group, winding resistance, tan delta, oil sampling and analysis, oil supply and filtration, and preventive maintenance programs.

  • Turns ratio & vector group
  • Winding resistance & tan delta
  • Oil sampling & analysis
  • Oil supply & filtration
  • Preventive maintenance programs
Ask about transformer testing
ON SITE · EGYPT
Combiner box & Isc/Voc checks: Field testing in front of the PV array
01 / 02Combiner box & Isc/Voc checksField testing in front of the PV array
IV CURVE · ILLUSTRATION
SERVICE 04

Solar PV & BESS

Planning, design, execution, testing and commissioning. Isc/Voc checks, IV curve verification, and inverter transformer station testing.

  • Planning & design
  • Execution
  • Isc / Voc checks
  • IV curve verification
  • Inverter transformer station testing
Plan your solar or BESS project
ON SITE · EGYPT
High-voltage cable testing: Resonant AC test system set up on site
01 / 01High-voltage cable testingResonant AC test system set up on site
SERVICE 05

Specialized testing

Thermal imaging, partial discharge, VLF and Hi-Pot cable tests, cable fault location, earthing system testing, and SCADA/SAS point-to-point signal testing.

  • Thermal imaging
  • Partial discharge
  • VLF & Hi-Pot cable tests
  • Cable fault location
  • Earthing system testing
  • SCADA/SAS point-to-point signals
Request a specialized test
ON SITE · EGYPT
Placing switchgear modules: Crane-lifted GIS module going into position
01 / 05Placing switchgear modulesCrane-lifted GIS module going into position
Positioning MV switchgear: The crew sliding a UniGear panel into its final position
02 / 05Positioning MV switchgearThe crew sliding a UniGear panel into its final position
GIS bus ducts and assembly: Gas-insulated switchgear taking shape inside the hall
03 / 05GIS bus ducts and assemblyGas-insulated switchgear taking shape inside the hall
GIS bays in line: Modules set and aligned, ready for interconnection
04 / 05GIS bays in lineModules set and aligned, ready for interconnection
HV bay structures: Gantries, insulators and bus ducts at the substation
05 / 05HV bay structuresGantries, insulators and bus ducts at the substation
SERVICE 06

Power system installation

Placement, wiring and interconnection of generators, transformers, switchgear, panels, protection and control systems, to design specification and safety standards.

  • Placement & rigging
  • Wiring & interconnection
  • Generators, transformers & switchgear
  • Protection & control systems
  • Design specification & safety standards
Talk to us about installation

Selected projects

Delivered to IEEE and IEC standards, alone or in consortium.

Abedous 500 MW Solar

220/33 kV substation and MV stations

Supplied manpower and test equipment, and led the testing and commissioning team to meet the energization schedule.

Obelisk Solar + BESS 1.1 GW

Consortium project

Protection relay, winding resistance, TTR, OBDV and IR testing for 8 inverter transformer stations; Isc/Voc analysis with PV Check Pro and IV curve verification for about 500 MW.

Saint Catherine, El Tagally Al-Azam

53 MV bays, 13 power transformers, kiosks

Protection relay testing, CB timing, busbar and CB contact resistance, Hi-Pot, CT/VT testing, function checks, operation and interlock tests.

ND7, 220/66/22 kV substation

Consortium project

Installation, testing and commissioning in consortium.

ND5, 220/66/22 kV substation

Lump sum

Testing and commissioning.

SOUL, 32 MV switchgear DBs

Full scope

Installation, testing and commissioning.

From first cable to energization

Where ECO Power Services sits in the power chain, and what we deliver at each stage.

Install

Mounting, cabling and terminations to spec.

Test

Relays, CT/VT, transformers, breakers, IV curves.

Commission

Functional, interlock and operation checks.

Energize

Hand-over on schedule, with 24/7 support.

Why ECO Power Services

Safety, quality and integrity in every operation.

01

Experienced engineers

Teams with deep field experience in installation, testing and commissioning.

02

Reliable equipment

Performance testing equipment that gives accurate, repeatable results.

03

Built around your site

Services tailored to each customer's scope, schedule and standards.

04

24/7 support

Round-the-clock response when something needs attention.

THANK YOU

Many thanks to our team and our supporters during the journey

Request a quote

Tell us about your site and scope. We reply by email.

  • info@ecopower-services.com
  • 01010179279 · 01111105620
  • October Gardens, Giza, Egypt

Opens your email app with the request addressed to info@ecopower-services.com.